| Sign In | Join Free | My fnxradio.com | 
              
  | 
      
Brand Name : GENY
Model Number : YC-1891D
Place of Origin : CHINA
MOQ : 1
Delivery Time : 60 work days
Certification : ISO, CE
Price : negotiate rates
Payment Terms : D/A,D/P,T/T,L/C
Supply Ability : 10 pcs/ 3 months
Packaging Details : Plywood cases
Type : YC1891D
Accuracy class : 0.05% / 0.02%
Max Voltage : 480V (P-N)
Max Current : 200A
Frequency : 40Hz ~ 70Hz
HS Code : 9030849000
Usage : Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Prepayment Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter
Universal Fully Automatic Stationary Three Phase Meter Test Equipment for Calibration of Electronic Energy Meter
|   |    YC1891D-6  |    YC1891D-12  |    YC1891D-24  |    YC1891D-48  |  
|   Number of meter positions  |    6  |    12  |    24  |    48  |  
|   Accuracy  |    0.05  |  |||
|   Power Source  |    YCS-101-250  |    YCS-101-600  |    YCS-101-1200  |    YCS-101-2500  |  
|   Standard Meter  |    SZ01A-K3  |  |||
|   MSVT  |    HJ200GL-6  |    HJ200GL-12  |    HJ200GL-24  |    HJ200GL-48  |  
|   QCD  |    D5 series  |  |||
|   Scanning Head  |    YCG-2 series  |  |||
|   Voltage  |  ||||
|   Test voltage output  |    24V – 288V or customized  |  |||
|   Power of the voltage output  |    100VA  |    250VA  |    500VA  |    1000VA  |  
|   Resolution  |    Better than 0.01% of full scale value of range  |  |||
|   Setting accuracy  |    Better than 0.05% at the final range value  |  |||
|   Stability  |    Better than 0.005%/h (integration time 150 s)  |  |||
|   Load regulation from 0-max. load  |    Better than 0.01%  |  |||
|   Distortion factor  |    Better than 0.3% for linear resistance load  |  |||
|   Harmonics  |    2nd – 21st free programmable  |  |||
|   Current  |  ||||
|   Test current output  |    1mA – 100A or customized,Max.200A  |    1mA – 100A  |  ||
|   Power of the current output  |    150VA  |    350VA  |    750VA  |    1500VA  |  
|   Resolution  |    Better than 0.01% of full scale value of range  |  |||
|   Setting accuracy  |    Better than 0.05% at the final range value  |  |||
|   Stability  |    Better than 0.005%/h (integration time 150 s)  |  |||
|   Load regulation from 0-max. load  |    Better than 0.01%  |  |||
|   Distortion factor  |    Better than 0.3% for linear resistance load  |  |||
|   Harmonics  |    2nd – 21st free programmable  |  |||
|   Phase angle  |  ||||
|   Range  |    0 -- 360°  |  |||
|   Resolution  |    0.01°  |  |||
|   Setting accuracy  |    0.1°  |  |||
|   Frequency  |  ||||
|   Range  |    45Hz – 65Hz  |  |||
|   Resolution  |    0.01Hz  |  |||
|   Error display  |  ||||
|   Type of error display  |    Red LED  |  |||
|   Resolution of the error displays  |    8 digits  |  |||
|   
  |  ||||
|   Voltage Supply  |    220V±10% or customized 50/60Hz±2Hz  |    3x220/380V±10% or customized 50/60Hz±2Hz  |  ||
|   Ambient temperature  |    -10°C -- +40°C  |  |||
|   Relative humidity  |    35% -- 85%  |  |||



| 
                                             | 
                
                        Automatic Electrical Tester Calibration Images |